ZYD-100
ZHONGNENG
8421299090
Features:
1, This double stage vacuum transformer oil purifier is high effective with a special booster named roots pump.
2, The vacuum oil purifier is portable and small size, so you can use it everywhere.
3, It is very suit to operate on line. Also it can be used to dry the electric equipment and input the oil into the electric equipment under the vacuum state.
4,The vacuum oil purifier is automatic control.
5, With the alarm, when the temperature and pressure exceed the index, all the parts will stopped.
6. High vacuum limiting vacuum less than 5pa, working vacuum less than 35pa.
7. Environment friendly.
8, Power cost less.
9, Strong filtration ability and stable working
10, With the engineer installation.
11, We can take the special order as the customer need.
Advantages:
Comparing with the single-stage vacuum oil purifier, series ZYD adds ROOTS vacuum system, second stage of separating system to improve the effect of purification which dewaters, degases and removes impurities more quickly, more completely and make the oils limiting voltage-withstand value much higher.
This machine also can remove free, soluble water, carbon, free and dissolved gases and particulate matters from insulating oil effectively and rapidly. As the bridge-type vacuum linking system that can filter and be an independent vacuum power supply, this machine can be vacuum treating the electric insulating devices. Series ZYD utilizes coacervation technology, coalescing technology, separating technology and refined purification technology.
Features:
1, This double stage vacuum transformer oil purifier is high effective with a special booster named roots pump.
2, The vacuum oil purifier is portable and small size, so you can use it everywhere.
3, It is very suit to operate on line. Also it can be used to dry the electric equipment and input the oil into the electric equipment under the vacuum state.
4,The vacuum oil purifier is automatic control.
5, With the alarm, when the temperature and pressure exceed the index, all the parts will stopped.
6. High vacuum limiting vacuum less than 5pa, working vacuum less than 35pa.
7. Environment friendly.
8, Power cost less.
9, Strong filtration ability and stable working
10, With the engineer installation.
11, We can take the special order as the customer need.
Advantages:
Comparing with the single-stage vacuum oil purifier, series ZYD adds ROOTS vacuum system, second stage of separating system to improve the effect of purification which dewaters, degases and removes impurities more quickly, more completely and make the oils limiting voltage-withstand value much higher.
This machine also can remove free, soluble water, carbon, free and dissolved gases and particulate matters from insulating oil effectively and rapidly. As the bridge-type vacuum linking system that can filter and be an independent vacuum power supply, this machine can be vacuum treating the electric insulating devices. Series ZYD utilizes coacervation technology, coalescing technology, separating technology and refined purification technology.
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V/ 50Hz/ 3Phase( As per your requirement) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 30 | 48 | 72 | 72 | 90 | 120 | |
Total Power | KW | 33 | 35 | 55 | 80 | 82 | 102 | 135 | |
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
Dimensions will be changed if any special type required
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V/ 50Hz/ 3Phase( As per your requirement) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 30 | 48 | 72 | 72 | 90 | 120 | |
Total Power | KW | 33 | 35 | 55 | 80 | 82 | 102 | 135 | |
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
Dimensions will be changed if any special type required